MD1 calibration Yield calculation

MD1 energy calibration, tune ratios, ED1 calibration

MD1 field [G]: MD1 setpoint [A]:
Mass number: Charge state:
ED1 setpoint voltage [kV]:
Please insert MD1, A and q to calculate the beam energy.


Please insert B and ED1 to calculate the mass-to-charge ratio (and q for mass).

Magnet Field
Q1 0.709
Q2 0.677
MD1 1
Q3 0.553
Q4 0.735
Q5 0.381
Q6 0.366
Q7 0.512
MD2 1.23
Q8 0.387
Q9 0.238
Q10 0.266
Magnet Setpoint
SX1 0.0528
SX2 0.0112
MD1 1
SX3 0.01
SX4 0.0974


Yield calculation

needed for R:
FC4 current [enA]: Transmission through target [%]:
Beam energy [AkeV]: Charge state: Run time [s]:
Target pressure [Torr]: Nelastic:



To calculate yield:
R [Torr/(AkeV)2]: Beam energy [AkeV]: Target pressure [Torr]:
Nelastic: Recoils Nrecoil: Charge state fraction [%]:
Efficiencies:
through separator [%]: through MCPs [%]: BGOs [%]:





Created by Ulrike
last modified Thu Jul 3 20:50 PDT 2008
Annika Lennarz